<?xml version="1.0" encoding="UTF-8"?>
<mets:mets xmlns:mets="http://www.loc.gov/METS/" xmlns:metsRights="http://cosimo.stanford.edu/sdr/metsrights/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:mads="http://www.loc.gov/mads/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:tef="http://www.abes.fr/abes/documents/tef">
<mets:metsHdr CREATEDATE="2023-01-23T11:33:59" ID="univ-lille-37080" RECORDSTATUS="complet" LASTMODDATE="2024-10-18T10:04:31">
<mets:agent ROLE="CREATOR">
<mets:name>Université de Lille</mets:name>
</mets:agent>
</mets:metsHdr>
<mets:dmdSec CREATED="2002-12-07T12:20:46" ID="desc_expr">
<mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_desc_these">
<mets:xmlData>
<tef:thesisRecord>
<dc:title xml:lang="fr">Couplage pression artérielle, pressions circuit, et débit pompe, sous ECMO veino-artérielle à pompe centrifuge</dc:title>
<dc:subject xml:lang="fr">ECMO</dc:subject>
<dc:subject xml:lang="fr">pression artérielle</dc:subject>
<dc:subject xml:lang="fr">hémolyse</dc:subject>
<dc:subject xml:lang="fr">pressions circuit</dc:subject>
<dc:subject xml:lang="fr">optimisation</dc:subject>
<dc:subject xsi:type="dcterms:DDC">610</dc:subject>
<tef:sujetRameau>
<tef:vedetteRameauNomCommun>
<tef:elementdEntree autoriteSource="Sudoc" autoriteExterne="15973987X">ECMO (médecine)</tef:elementdEntree>
</tef:vedetteRameauNomCommun>
<tef:vedetteRameauNomCommun>
<tef:elementdEntree autoriteSource="Sudoc" autoriteExterne="027798143">Pression artérielle</tef:elementdEntree>
</tef:vedetteRameauNomCommun>
<tef:vedetteRameauNomCommun>
<tef:elementdEntree autoriteSource="Sudoc" autoriteExterne="027827593">Hémolyse</tef:elementdEntree>
</tef:vedetteRameauNomCommun>
<tef:vedetteRameauNomCommun>
<tef:elementdEntree autoriteSource="Sudoc.FMesh" autoriteExterne="040802663">Oxygénation extracorporelle sur oxygénateur à membrane</tef:elementdEntree>
<tef:subdivision autoriteSource="Sudoc.FMesh" autoriteExterne="040839486" type="subdivisionDeForme">Dissertation universitaire</tef:subdivision>
</tef:vedetteRameauNomCommun>
<tef:vedetteRameauNomCommun>
<tef:elementdEntree autoriteSource="Sudoc.FMesh" autoriteExterne="171871782">Pression artérielle</tef:elementdEntree>
<tef:subdivision autoriteSource="Sudoc.FMesh" autoriteExterne="040839486" type="subdivisionDeForme">Dissertation universitaire</tef:subdivision>
</tef:vedetteRameauNomCommun>
<tef:vedetteRameauNomCommun>
<tef:elementdEntree autoriteSource="Sudoc.FMesh" autoriteExterne="040717526">Hémolyse</tef:elementdEntree>
<tef:subdivision autoriteSource="Sudoc.FMesh" autoriteExterne="040839486" type="subdivisionDeForme">Dissertation universitaire</tef:subdivision>
</tef:vedetteRameauNomCommun>
</tef:sujetRameau>
<dcterms:abstract xml:lang="fr">Introduction : L’ECMO veino-artérielle périphérique (ECMO-VA) est
un support hémodynamique indiqué en cas de choc cardiogénique
réfractaire afin de restaurer un débit suffisant et une pression de perfusion
systémique adaptée. Cependant la relation entre le débit délivré et
la pression artérielle moyenne (PAM) est peu évaluée dans ce contexte.
Par ailleurs, les contraintes mécaniques générées au sein du circuit
(niveau de pression, cavitation, cisaillement, type d’écoulement) n’ont
jamais été confrontées avec les gains en PAM obtenue. Or ces contraintes
sont à l’origine de complications hématologiques (hémolyse,
SIRS, syndrome de Willebrand acquis. . . ) pouvant impacter le pronostic.
Matériel et méthodes : Étude prospective et observationnelle pilote
portant sur 12 patients assistés par ECMO-VA dont les objectifs sont : 1)
étudier la relation entre la PAM et le débit de pompe (Qm) ; 2) étudier
l’association entre la variation des pressions du circuit (DP) et Qm ; 3)
Identifier des indices permettant de décrire un couplage entre Qm -
PAM - DP.
Résultats : La PAM augmente avec le Qm de façon significative, avec
un effet de saturation pour les niveaux de Qm élevés. Une variabilité
inter et intra-individuelle est à noter. Pour une majoration de Qm,
l’augmentation relative de DP est plus importante que celle de la PAM
avec des niveaux d’augmentation 3 à 5 fois plus élevés. La pression
d’entrée peut atteindre des valeurs négatives associées à une hémolyse
plus importante pour des débits usuels (&lt; 5 L/min). L’analyse des
différentes courbes permet de dégager la valeur de Qm entre [4 ? 4, 5] L/min comme seuil le plus élevé assurant une maximisation de la
PAM et une minimisation des pressions du circuit.
Conclusion : Dans cette étude pilote évaluant le couplage Qm - PAM
- DP, nous observons que le gain en PAM au-delà de 4-4, 5 L/min
semble saturable, cela au prix d’une augmentation de DP à des niveaux
exposant au traumatisme de certains composants corpusculaires et
protéiques du sang.</dcterms:abstract>
<dcterms:abstract xml:lang="en">Introduction: Peripheral veno-arterial ECMO (ECMO-VA) is the mainstay
for hemodynamic support for refractory cardiogenic shock by
delivering sufficient flow and restoring systemic perfusion pressure.
However, the relationship between the delivered flow rate (Qm) and the
mean arterial pressure (MAP) is little to not evaluated. Moreover, the
relation between mechanical constraints generated within the circuit
(pressure level, cavitation, shear stress, type of flow) and the increase in
MAP has never been studied. Of concern, these constraints may lead
to hematological complications (hemolysis, SIRS, acquired Willebrand
syndrome,..) that can impact the prognosis.
Material and methods: Prospective observational pilot study that
included 12 patients supported by VA-ECMO whose objectives are: 1)
Studying the changes of MAP as a function of Qm; 2) Studying the
association between circuit pressures variations and Qm; 3) Identifying
indexes to describe a coupling between Qm - PAM - pressures on the
circuit.
Results: MAP increases with Qm significantly, with a saturation effect
for high Qm levels. Inter- and intra-individual variability is noted. For
an increase in Qm, the increase in circuit pressures is 3 to 5 times greater
than the MAP obtained. The inlet pressure can reach negative values
associated with greater hemolysis for usual flow rates (&lt; 5 L/min).With
the analysis of the different curves we identified an optimal threshold of
Qm between [4 ? 4.5] L/min, ensuring MAP maximization and circuit
pressures minimization.
Conclusion: In this pilot study evaluating the coupling Qm – MAP–
circuit pressures, we observe that the association between MAP and Qm
was saturable. This saturation threshold was reached for Qm values of
4 ? 4.5 L/min, beyond which dramatic increases in circuit pressures
that promotes blood trauma was observed.</dcterms:abstract>
<dc:type>Electronic Thesis or Dissertation</dc:type>
<dc:type xsi:type="dcterms:DCMIType">Text</dc:type>
<dc:language xsi:type="dcterms:RFC3066">fr</dc:language>
</tef:thesisRecord>
</mets:xmlData>
</mets:mdWrap>
</mets:dmdSec>
<mets:dmdSec CREATED="2002-12-07T12:20:46" ID="desc_edition">
<mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_desc_edition">
<mets:xmlData>
<tef:edition>
<dcterms:medium xsi:type="dcterms:IMT">application/pdf</dcterms:medium>
<dcterms:extent>1 : 0 Ko</dcterms:extent>
<dc:identifier xsi:type="dcterms:URI">https://pepite-depot.univ-lille.fr/RESTREINT/Th_Medecine/2022/2022ULILM510.pdf</dc:identifier>
</tef:edition>
</mets:xmlData>
</mets:mdWrap>
</mets:dmdSec>
<mets:amdSec>
<mets:techMD ID="admin_expr">
<mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_admin_these">
<mets:xmlData>
<tef:thesisAdmin>
<tef:auteur>
<tef:nom>Khaoua</tef:nom>
<tef:prenom>Ibtissame</tef:prenom>
<tef:dateNaissance>1988-12-07</tef:dateNaissance>
<tef:nationalite scheme="ISO-3166-1">FR</tef:nationalite>
<tef:autoriteExterne autoriteSource="Sudoc">249721732</tef:autoriteExterne>
</tef:auteur>
<dc:identifier xsi:type="tef:NNT">2022ULILM510</dc:identifier>
<dc:identifier xsi:type="tef:nationalThesisPID"/>
<dcterms:dateAccepted xsi:type="dcterms:W3CDTF">2022-12-07</dcterms:dateAccepted>
<tef:thesis.degree>
<tef:thesis.degree.discipline xml:lang="fr">Médecine. Anesthésie Réanimation</tef:thesis.degree.discipline>
<tef:thesis.degree.grantor>
<tef:nom>Université de Lille (2022-...)</tef:nom>
<tef:autoriteInterne>thesis.degree.grantor_1</tef:autoriteInterne>
<tef:autoriteExterne autoriteSource="Sudoc">259265152</tef:autoriteExterne>
</tef:thesis.degree.grantor>
<tef:thesis.degree.level>Doctorat de médecine</tef:thesis.degree.level>
</tef:thesis.degree>
<tef:theseSurTravaux>non</tef:theseSurTravaux>
<tef:avisJury>oui</tef:avisJury>
<tef:directeurThese>
<tef:nom>Moussa</tef:nom>
<tef:prenom>Mouhamed</tef:prenom>
<tef:autoriteInterne>intervenant_1</tef:autoriteInterne>
<tef:autoriteExterne autoriteSource="Sudoc">164373411</tef:autoriteExterne>
</tef:directeurThese>
<tef:oaiSetSpec>ddc:610</tef:oaiSetSpec>
<tef:MADSAuthority authorityID="intervenant_1" type="personal">
<tef:personMADS>
<mads:namePart type="family">Moussa</mads:namePart>
<mads:namePart type="given">Mouhamed</mads:namePart>
</tef:personMADS>
</tef:MADSAuthority>
<tef:MADSAuthority authorityID="thesis.degree.grantor_1" type="corporate">
<tef:personMADS>
<mads:namePart>Université de Lille (2022-...)</mads:namePart>
<mads:description>Université de Lille</mads:description>
</tef:personMADS>
</tef:MADSAuthority>
</tef:thesisAdmin>
</mets:xmlData>
</mets:mdWrap>
</mets:techMD>
<mets:techMD ID="file_1">
<mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_tech_fichier">
<mets:xmlData>
<tef:meta_fichier>
<tef:encodage>Unicode</tef:encodage>
<tef:formatFichier>PDF</tef:formatFichier>
<tef:taille>50</tef:taille>
</tef:meta_fichier>
</mets:xmlData>
</mets:mdWrap>
</mets:techMD>
<mets:rightsMD ID="dr_expr_thesard">
<mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_droits_auteur_these">
<mets:xmlData>
<metsRights:RightsDeclarationMD>
<metsRights:Context CONTEXTCLASS="GENERAL PUBLIC">
<metsRights:Permissions COPY="true" DELETE="false" DISCOVER="true" DISPLAY="false" DUPLICATE="true" MODIFY="false" PRINT="true"/>
</metsRights:Context>
</metsRights:RightsDeclarationMD>
</mets:xmlData>
</mets:mdWrap>
</mets:rightsMD>
<mets:rightsMD ID="dr_expr_univ">
<mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_droits_etablissement_these">
<mets:xmlData>
<metsRights:RightsDeclarationMD>
<metsRights:Context CONTEXTCLASS="GENERAL PUBLIC">
<metsRights:Permissions COPY="true" DELETE="false" DISCOVER="true" DISPLAY="true" DUPLICATE="true" MODIFY="false" PRINT="true"/>
</metsRights:Context>
</metsRights:RightsDeclarationMD>
</mets:xmlData>
</mets:mdWrap>
</mets:rightsMD>
<mets:rightsMD ID="dr_version">
<mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_droits_version">
<mets:xmlData>
<metsRights:RightsDeclarationMD>
<metsRights:Context CONTEXTCLASS="GENERAL PUBLIC">
<metsRights:Permissions COPY="true" DELETE="false" DISCOVER="true" DISPLAY="true" DUPLICATE="true" MODIFY="false" PRINT="true"/>
</metsRights:Context>
</metsRights:RightsDeclarationMD>
</mets:xmlData>
</mets:mdWrap>
</mets:rightsMD>
</mets:amdSec>
<mets:fileSec>
<mets:fileGrp ID="FGrID1" USE="archive_et_diffusion">
<mets:file ID="FID1" ADMID="file_1" MIMETYPE="application/pdf" USE="maitre">
<mets:FLocat LOCTYPE="URL" xlink:href="https://pepite-depot.univ-lille.fr/RESTREINT/Th_Medecine/2022/2022ULILM510.pdf"/>
</mets:file>
</mets:fileGrp>
</mets:fileSec>
<mets:structMap TYPE="logical">
<mets:div ADMID="dr_expr_thesard dr_expr_univ admin_expr" CONTENTIDS="www.univ-lille.fr/uid/univ-lille-37080/oeuvre" DMDID="desc_expr" TYPE="THESE">
<mets:div ADMID="dr_version" CONTENTIDS="www.univ-lille.fr/uid/univ-lille-37080/oeuvre/version" TYPE="VERSION_COMPLETE">
<mets:div CONTENTIDS="www.univ-lille.fr/uid/univ-lille-37080/oeuvre/version/edition" DMDID="desc_edition" TYPE="EDITION">
<mets:fptr FILEID="FGrID1"/>
</mets:div>
</mets:div>
</mets:div>
</mets:structMap>
</mets:mets>
