<?xml version="1.0" encoding="UTF-8"?>
<mets:mets xmlns:mets="http://www.loc.gov/METS/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:metsRights="http://cosimo.stanford.edu/sdr/metsrights/" xmlns:tef="http://www.abes.fr/abes/documents/tef" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/METS/ http://www.abes.fr/abes/documents/tef/recommandation/tef_schemas.xsd">
<mets:metsHdr CREATEDATE="2021-04-12T11:55:42" ID="univ-lille-28396" LASTMODDATE="2021-04-12T16:20:42" RECORDSTATUS="complet">
<mets:agent ROLE="CREATOR">
<mets:name>Université Lille1 - Sciences et Technologies</mets:name>
</mets:agent>
</mets:metsHdr>
<mets:dmdSec CREATED="2021-04-12T11:55:42" ID="desc_expr">
<mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_desc_these">
<mets:xmlData>
<tef:thesisRecord>
<dc:title xml:lang="fr">Dispositifs radiométriques pour usage industriel et médical
: réalisation et modélisation d'une nouvelle génération d'antenne-capteur</dc:title>
<dc:subject xsi:type="dcterms:DDC">681.2</dc:subject>
<tef:sujetRameau>
<tef:vedetteRameauNomCommun>
<tef:elementdEntree autoriteExterne="02735962X" autoriteSource="Sudoc">Antennes (électronique)</tef:elementdEntree>
</tef:vedetteRameauNomCommun>
<tef:vedetteRameauNomCommun>
<tef:elementdEntree autoriteExterne="027394239" autoriteSource="Sudoc">Thermométrie</tef:elementdEntree>
</tef:vedetteRameauNomCommun>
<tef:vedetteRameauNomCommun>
<tef:elementdEntree autoriteExterne="027861295" autoriteSource="Sudoc">Radiométrie</tef:elementdEntree>
</tef:vedetteRameauNomCommun>
</tef:sujetRameau>
<dc:type xsi:type="dcterms:DCMIType">Text</dc:type>
<dc:type>Electronic Thesis or Dissertation</dc:type>
<dc:language xsi:type="dcterms:RFC3066">fr</dc:language>
<dcterms:abstract xml:lang="fr">La radiometrie micro-onde permet de determiner la temperature d'un milieu dissipatif a partir de la mesure de la puissance electromagnetique d'origine thermique rayonnee spontanement par celui-ci. Elle fournit une information de temperature en volume et presente l'avantage d'etre non invasive et non destructive. La procedure de la mesure effectuee en champ proche est decrite tout d'abord et nous presentons les ameliorations technologiques apportees au radiometre de seconde generation a deux references internes de temperatures afin d'etendre le champ d'applications de ces dispositifs. Les caracteristiques metrologiques de linearite et de sensibilite des radiometres a large bande passante et a bande etroite sont presentees. Une methodologie de prise en compte d'un cable additionnel, insere entre le capteur et le radiometre, impose par les conditions de mesure sur site, est introduite et validee. Ce systeme radiometrique est associe a un nouveau type de capteurs froids dont nous faisons la description technique et argumentons les avantages. Une modelisation electromagnetique basee sur l'approche dans le domaine spectral vise a en definir les caracteristiques : adaptation electromagnetique, diagramme de reception. L'influence des dimensions du capteur froid est egalement etudiee afin de definir la structure optimale selon l'application. Les resultats d'experimentations menees en laboratoire mais aussi sur site industriel et en milieu medical sont ensuite decrits. Ils mettent en lumiere le fort potentiel qu'offre la radiometrie micro-onde pour le suivi de la temperature au sein d'aliments en phase de surcongelation ou de cuisson. Son interet et sa validite dans le controle de process industriel de la temperature de produits agro-alimentaires</dcterms:abstract>
</tef:thesisRecord>
</mets:xmlData>
</mets:mdWrap>
</mets:dmdSec>
<mets:dmdSec CREATED="2021-04-12T11:55:42" ID="desc_version">
<mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_desc_version">
<mets:xmlData>
<tef:version/>
</mets:xmlData>
</mets:mdWrap>
</mets:dmdSec>
<mets:dmdSec CREATED="2021-04-12T11:55:42" ID="desc_edition">
<mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_desc_edition">
<mets:xmlData>
<tef:edition>
<dcterms:medium xsi:type="dcterms:IMT">application/pdf</dcterms:medium>
<dcterms:extent>1 : 1 Mo</dcterms:extent>
<dc:identifier xsi:type="dcterms:URI">https://pepite-depot.univ-lille.fr/LIBRE/Th_Num/2000/50376-2000-462.pdf
</dc:identifier>
</tef:edition>
</mets:xmlData>
</mets:mdWrap>
</mets:dmdSec>
<mets:amdSec>
<mets:techMD ID="admin_expr">
<mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_admin_these">
<mets:xmlData>
<tef:thesisAdmin>
<tef:auteur>
<tef:nom>Vanoverschelde</tef:nom>
<tef:prenom>Carine</tef:prenom>
<tef:dateNaissance>1900-01-01</tef:dateNaissance>
<tef:autoriteExterne autoriteSource="Sudoc">122765761</tef:autoriteExterne>
</tef:auteur>
<dc:identifier xsi:type="tef.NNT">2000LIL10168</dc:identifier>
<dc:identifier xsi:type="tef.nationalThesisPID"/>
<dcterms:dateAccepted xsi:type="dcterms:W3CDTF">2000-01-01
</dcterms:dateAccepted>
<tef:thesis.degree>
<tef:thesis.degree.discipline xml:lang="fr">Electronique</tef:thesis.degree.discipline>
<tef:thesis.degree.grantor>
<tef:nom>Université Lille1 - Sciences et Technologies</tef:nom>
<tef:autoriteExterne autoriteSource="Sudoc">026404184</tef:autoriteExterne>
</tef:thesis.degree.grantor>
<tef:thesis.degree.level>Doctorat</tef:thesis.degree.level>
</tef:thesis.degree>
<tef:theseSurTravaux>non</tef:theseSurTravaux>
<tef:avisJury>oui</tef:avisJury>
<tef:directeurThese>
<tef:nom>Chivé</tef:nom>
<tef:prenom>Maurice</tef:prenom>
<tef:autoriteExterne autoriteSource="Sudoc">059847913</tef:autoriteExterne>
</tef:directeurThese>
<tef:oaiSetSpec>ddc:680</tef:oaiSetSpec>
</tef:thesisAdmin>
</mets:xmlData>
</mets:mdWrap>
</mets:techMD>
<mets:techMD ID="file_1">
<mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_tech_fichier">
<mets:xmlData>
<tef:meta_fichier>
<tef:encodage>ASCII</tef:encodage>
<tef:formatFichier>PDF</tef:formatFichier>
<tef:taille>9999</tef:taille>
</tef:meta_fichier>
</mets:xmlData>
</mets:mdWrap>
</mets:techMD>
<mets:rightsMD ID="dr_expr_thesard">
<mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_droits_auteur_these">
<mets:xmlData>
<metsRights:RightsDeclarationMD>
<metsRights:Context CONTEXTCLASS="GENERAL PUBLIC">
<metsRights:Permissions COPY="true" DELETE="false" DISCOVER="true" DISPLAY="true" DUPLICATE="true" MODIFY="false" PRINT="true"/>
</metsRights:Context>
</metsRights:RightsDeclarationMD>
</mets:xmlData>
</mets:mdWrap>
</mets:rightsMD>
<mets:rightsMD ID="dr_expr_univ">
<mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_droits_etablissement_these">
<mets:xmlData>
<metsRights:RightsDeclarationMD>
<metsRights:Context CONTEXTCLASS="GENERAL PUBLIC">
<metsRights:Permissions COPY="true" DISCOVER="true" DISPLAY="true" DUPLICATE="true" MODIFY="false" PRINT="true"/>
</metsRights:Context>
</metsRights:RightsDeclarationMD>
</mets:xmlData>
</mets:mdWrap>
</mets:rightsMD>
<mets:rightsMD ID="dr_version">
<mets:mdWrap MDTYPE="OTHER" OTHERMDTYPE="tef_droits_version">
<mets:xmlData>
<metsRights:RightsDeclarationMD>
<metsRights:Context CONTEXTCLASS="GENERAL PUBLIC">
<metsRights:Permissions COPY="true" DELETE="false" DISCOVER="true" DISPLAY="true" DUPLICATE="true" MODIFY="false" PRINT="true"/>
</metsRights:Context>
</metsRights:RightsDeclarationMD>
</mets:xmlData>
</mets:mdWrap>
</mets:rightsMD>
</mets:amdSec>
<mets:fileSec>
<mets:fileGrp ID="FGrID1" USE="archive">
<mets:file ADMID="file_1" ID="FID1" MIMETYPE="application/pdf" USE="maitre">
<mets:FLocat LOCTYPE="URL" xlink:href="https://pepite-depot.univ-lille.fr/LIBRE/Th_Num/2000/50376-2000-462.pdf"/>
</mets:file>
</mets:fileGrp>
</mets:fileSec>
<mets:structMap TYPE="logical">
<mets:div ADMID="dr_expr_thesard dr_expr_univ admin_expr" CONTENTIDS="www.univ-lille.fr/uid/univ-lille-28396/oeuvre" DMDID="desc_expr" TYPE="THESE">
<mets:div ADMID="dr_version" CONTENTIDS="www.univ-lille.fr/uid/univ-lille-28396/oeuvre/version" TYPE="VERSION_COMPLETE">
<mets:div CONTENTIDS="www.univ-lille.fr/uid/univ-lille-28396/oeuvre/version/edition" DMDID="desc_edition" TYPE="EDITION">
<mets:fptr FILEID="FGrID1"/>
</mets:div>
</mets:div>
</mets:div>
</mets:structMap>
</mets:mets>
